In order to receive mitigation discounts a home must have certain features which roof retrofitters can add for you.
Retrofit permit roof to wall clips florida.
The legislation limited the required expenditure to 15 of the cost of the re roofing.
Priority shall be given to connecting the corners of roofs to walls below where the spans of the roofing members are greatest.
6 feet from the.
Sufficient eave sheathing shall be removed to expose a minimum of 6 feet of framing members.
Roof sheathing shall be attached in compliance with the florida building code florida statue 553 844 and the hurricane mitigation retrofit manual.
Florida homeowners insurance policies have mitigation discounts for hurricane straps or clips also known as the roof to wall connection discount.
Replacement of the existing roof cost is 10 000 00 x 15 1 500 00 this amount is required to be spent on roof to wall connection retrofits.
One possible way is to gain access through the eave area which may be exposed or through the soffit which is the flat surface at the eaves that forms a sort of ceiling where the roof overhangs the.
For houses with both hip and gable roof ends the priority shall be to retrofit the gable end roof to wall connections unless the width of the hip end is more than 1 5 times greater than the width of the gable end.
The following specific guidelines were developed for the florida building commission to support a mandate by the state legislature that requires houses valued at more than 300 000 to include some roof to wall retrofits as part of a re roofing project.
Priority shall be given to connecting the corners of roofs to walls below where the spans of the roofing members are greatest.
If you are not currently receiving this discount or are not sure please contact us and we will perform a free evaluation.
There are several ways to gain access to the roof to wall connections in masonry houses.
For gable end roofs the florida code requires that you start by tying down roof framing members within 6 feet of each corner.
For houses with both hip and gable roof ends the priority shall be to retrofit the gable end roof to wall connections unless the width of the hip end is more than 1 5 times greater than the width of the gable end.
Retrofitting roof to wall connections in masonry houses.
Roof to wall connections a.
For hip roofs the code specifies that hip and girder rafters or trusses be connected to exterior wall plates.
For 16 inch on center framing that means connecting four trusses at each end of the house.